<LOGO>
FM Transmitter Measurement Report
Created: 2026-03-21 09-21-11
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 40 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 52 kHz 12037 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,0 dBr -0,25 dBr 0,3 dBr 3,6
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 9:21, 21.03.2026
RT
"Ranni Plus - Policie pokracuje ve vysetrovani patecniho pozar..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 52 kHz MIN: 6 kHz % above 77 kHz: 0,0000 Acquired: 2026/03/21 9:21:07 Total samples: 12037 Equivalent time: 0:10:01 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 0,3 dBr MIN: -1,0 dBr AVE: -0,25 dBr % above 0,2 dBr: 3,6 Last value: -1,0 dBr (2026/03/21 9:21:07) 09:08 09:10 09:12 09:14 09:16 09:18 09:20 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality